Product Details:
Place of Origin: China
Brand Name: KINGSINE
Certification: ISO9001,CE
Model Number: K3166i
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Delivery Time: 15 working days
Payment Terms: T/T in advanced, L/C
Supply Ability: 50 sets/month
Detailed Product Description
High Light:

protective relay tester

,

relay protection tester

 

 K3166i Universal Relay Test Set

 

                 (All-in-one design,complying IEC61850 SV & GOOSE)                                                             

 

Output Current: 6×35A@450VA max. 

 

                                3×70A@850VA max.  

 

  Output Voltage: 7×310V@90VA max.
                         

                          

Features

 

 

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.

 

1. Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc.

 

2. 100/1000Mbit Fiber ports for SMV and GOOSE simulations.

 

3. 6×35A & 7×310V independent high burden output channels.

 

4. 13 channels independent low-level signal outputs.

 

5. AC/DC measurement (8 channels inputs,class 0.1,0-600V/0-5A,auto range).

 

6. Transducer calibartion (class 0.02).

 

7. Energy meter calibration ( Mechanical & Electronic meters ).

 

8. Analog and Binary Transient Record.

 

9. Transient play back up to 3KHZ.

 

10. Light weight <18kg

 

11. Fully function KRT software testing modules.

 

12. 3-Years guarantee of free repair and life-long maintenance.

 

13. Free software upgrade.

 

 

Ordering Ref.

 

Model Current Outputs Voltage Outputs
K3166i 6×35A@450VA max / 3×70A@850VA max 7×310V@90VA max
K3163i 6×35A@450VA max / 3×70A@850VA max 4×310V@124VA max
K3130i 3×35A@450VA max 4×310V@124VA max
K3166 6×35A@450VA max / 3×70A@850VA max 7×130V@75VA max
K3163 6×35A@450VA max / 3×70A@850VA max 4×130V@75VA max
K3130 3×35A@450VA max 4×130V@75VA max

 

 

Application

 

 

Testing Items                                                                                     ANSI® No.                                  

 

 IEC61850 numerical IEDs relay & merge unit                                              --                                             

 

 Distance protection relay                                                                            21

 

 Synchronising or synchronism-check relays                                               25                                            

 

 Undervoltage relays                                                                                    27

 

 Directional Power relays                                                                             32                                            

 

 Undercurrent or underpower relays                                                            37

 

 Negative sequence overcurrent relays                                                       46                                            

 

 Overcurrent/ground fault relays                                                                 50

 

 Inverse time overcurrent/ground fault relays                                              51                                            

 

 Power factor relays                                                                                    55

 

 Overvoltage relays                                                                                     59                                            

 

 Voltage or current balance relays                                                              60

 

 Directional overcurrent relays                                                                    67                                             

 

 Directional ground fault relays                                                                   67N

 

 DC overcurrent relays                                                                                76                                             

 

 Phase-angle measuring or out-of-step protection relays                            78

 

 Automatic reclosing devices                                                                       79                                            

 

 Frequency relays                                                                                       81

 

 Motor overload protection relays                                                                86                                             

 

 Differential protection relays                                                                       87

 

 Directional voltage relays                                                                           91                                             

 

 Voltage and power directional relays                                                         92

 

 Tripping relays                                                                                           94                                             

 

 Voltage regulating relays                                                                            --

 

 Overimpedance relays, Z>                                                                          --                                              

 

 Underimpedance relays, Z                                                                          --

 

 Time-delay relays                                                                                       --                                               

 

 

 

Characteristic

 

 

1. 13 Channels (6×35A & 7×310V) outputs, each output channels are independent and simultaneous.

 

2. Variable battery simulator, DC 0-350V, 140Watts max.

 

3. 13 Low-level channels outputs up to 8Vac/10Vdc max.

 

4. 0-600V / 0-5A AC/DC measurement in 0.1 class.

 

5. Graphical test modules and templates for testing of various relays.

 

6. Quick relay testing facility in Manual mode.

 

7. Shot/Search/Check, Point & Click testing.

 

8. RIO/XRIO import & export facility.

 

9. Switch on to fault test(SOTF).

 

10. Power system model for dynamic testing.

 

11. Inbuilt GPS and IRIG-B sync end-to-end testing.

 

12. Online Vector display.

 

13. Automatic test results assume.

 

14. Automatic test report creation.

 

15. Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.

 

 

Parameter

 

 

 Voltage Outputs
 Output Range & Power  7×310V ac (L-N)  90VA max each
 3×620V ac (L-L)  180VA max each
 3×350V dc (L-N)  140W max each
 Accuracy  AC:<0.03%Rd + 0.01Rg Typ. / <0.07%Rd + 0.03Rg Guar.
 DC: ±10mV @<5V,±0.5% @ ≥5V
 Resolution  1mV
 Distortion  <0.05% Typ. / <0.1% Guar.
 Current Outputs
 Output Range & Power  6×35A ac(L-N)  450VA max each
 3×70A ac(2L-N)  850VA max each
 1×100A ac(6L-N)  1200VA max
 3×20A dc(L-N)  300W max each
 Accuracy  AC:<0.05%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar.
 DC: ±5mA @<1A,±0.5% @ ≥1A
 Resolution  1mA
 Distortion  <0.05%Typ. / <0.1% Guar.
 13 Low-Level Channel Outputs
 Quantity  13 Channels, 16 pin aviation socket
 Voltage outputs range  AC 0-8V, DC 0-10V
 Current outputs range  Nominal 2mA, 10mA max transient
 Output Power  ≥0.5VA
 Accuracy  (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.
 (0.8~8 Vrms):<0.02% Typ. / <0.05% Guar.
 Resolution  0.25mV
 Distortion(THD%)  <0.05%Typ. / <0.1% Guar.
 Frequency & Phase Angle
 Frequency Range  DC~1KHZ, 3KHZ transient
 Frequency Accuracy  ±1ppm
 Frequency Resolution  0.001Hz
 Phase Range  -360°~360°
 Phase Accuracy  <0.05°Typ. / <0.1° Guar. 50/60Hz
 Phase Resolution  0.001°
 IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
 Fiber Ports

 2×100Base-FX Full Duplex,LC type


 (Optional to 10/100Mbit, Ethernet RJ45 type)

 Fiber Type  62.5/125um (Multiple optical fiber, Orange Red)
 Wavelength  1310nm
 Transmit Distance  >1Km
 Indicator

 Spd Green(light):Valid connection


 Link/Act Yellow(Blinking): Data exchanging

 Note: All hardware of this module are ready for active.
 Aux. DC Voltage Source(Battery simulator)
 Range  0~350V @ 140W max
 Accuracy  0.5%Rg Guar.
 Binary Input
 Quantity  8 pairs
 Type  wet/dry, measurement
 Threshold  10~600Vdc or potential free, Programmable
 Time resolution  100us
 Debounce time  0~25ms(Software Controlled)
 Time range  Infinite
 Time errors  ±1ms @ 0.001~1s, ±0.1% @>1s
 Galvanic isolation  4 isolated with each 2 pairs
 Binary Output(Relay Type)
 Quantity  4pairs
 Type  Potential free relay contacts,software controlled
 Break Capacity AC  Vmax: 400Vac / Imax:8A / Pmax:2500VA
 Break Capacity DC  Vmax: 300Vdc / Imax:5A / Pmax:150W
 Binary Output (Semiconductor Type)
 Quantity  4pairs
 Type  Open-collector, 14 pin Aviation socket
 Break Capacity DC

 5~15Vdc / 5mA, 10mA max


 AC not permit

 Response time  100us
 Synchronization
 Synchronization Mode   GPS, SMA type antenna connector / IRIG-B / FT3 IEEE1588
 Power supply & Environment
 Nominal Input Voltage  100~240Vac
 Permissible Input Voltage  85~264Vac, 125~350VDC
 Nominal Frequency  50/60Hz
 Permissible Frequency  45Hz~65Hz
 Power Consumption  1500 VA max
 Connection Type  Standard AC socket 60320
 Operating Temperature  -10℃~55℃
 Storage Temperature  -20℃~70℃
 Humidity  <95%RH, non-condensing
 Others
 PC Connection  RJ45 Ethernet, 10/100/1000M
 Grounding Terminal  4mm banana socket
 Weight  18Kg
 Dimensions(W×D×H)  468×375×164(mm)

 

 

 

Optional Modules

 

 

 DC Measurement Input (Transducer calibrator)                 

 

◆ Voltage input

     

     Range: 0~±10V dc

     

     Max Input: ±11V dc

     

     Accuracy: <0.02% rg Typ. / <0.05% rg Guar.

     

     Input Impedance: 1M ohm

 

◆ Current Input

     

     Range: 0~±1mA / 1~20mA, auto range

     

     Max Input: 600mA

     

     Accuracy: <0.02% rg Typ. / <0.05% rg Guar.

   

     Input Impedance: 15 ohm

 

 

 AC / DC Measurement Input( Standard meter )                     

 

◆  Input Quantity: 8 channels (blend with binary input pairs).

 

◆  Voltage rang: 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V).

 

◆  Voltage accuracy: <0.1% Rg

 

◆  Current range: 0~5Arms (Clamp input, 30Arms optional).

 

◆  Current accuracy: <0.1% Rg.

 

◆  Sample rate: 10KHz.

 

◆  Input impedance: 600KΩ

 

◆  Frequency range: 45~65Hz, Accuracy<0.01Hz.

 

◆  Phase accuracy: 0~360°,<0.2° Typ.

 

 

  Transient Recorder                                                                         

 

◆  Input Quantity: 8 input channels (blend with binary input pairs).

 

◆  Recorder time: Max 50 Sec.

 

 

 Energy Meter Calibration                                                                

 

◆  Sensor Usage: Mechanical meters / Electronic meters.

 

◆  Sensor Output: High level : >4.5V, Low level: <0.2V.

 

◆  Pulse Input: 1 pulse input port.

 

◆  Pulse Range: 500KHz pulse input Max.

 

◆  Pulse Output: 1 Transistor output, Open-collector, 5-15Vdc/5mA.

Contact Details
Kingsine Electric Automation Co., Ltd.

Contact Person: Amy

Tel: +8613603051120

Send your inquiry directly to us (0 / 3000)